150 Watt High-Pressure Sodium to LED Equivalent

By Editorial Team • Updated October 10, 2026

Advertiser Disclosure: As an Amazon Associate, we earn a commission from qualifying purchases made through our links. This compensation helps support our independent research and content creation at no additional cost to you. Product recommendations are made independently based on spec audits and performance standards.

Editorial Integrity: Our recommendations are based on verified manufacturer specifications, official certification databases (such as Energy Star and DLC), and careful analysis of long-term owner reviews. Our editorial team does not receive direct compensation from our advertisers.

Replacing a 150W High-Pressure Sodium bulb is one of the most effective ways to reduce energy costs. Modern LED replacements use only 80–110W to produce the same 14,400 lumens.

Quick answer: A 150W High-Pressure Sodium lamp is rated at about 16,000 initial lumens and averages about 14,400 lumens over its life. The LED equivalent is 80–110W for a lamp-for-lamp swap, and about the same (~80W) if you replace the whole fixture (see the worked example below). Either way, you replace a system that draws ~190W once the ballast is counted.

150W High-Pressure Sodium equivalent
14,400 lumens · Uses 50% less energy
Estimated annual savings: $54.09/year
(Based on 12 hours/day usage at $0.13/kWh. System wattage includes ballast factor.)
Lumie
Lumie's Tip: Choose high-efficiency LEDs with matching base types to enjoy maximum reliability and energy savings.
Check Prices for 80–110W LED Bulbs on Amazon →

Energy Savings Calculation

Current Bulb System 190 Watts (with ballast)
LED Replacement 80–110W
Lumen Output 14,400 lm
Efficacy 151.6 lm/W
Annual Energy Saved 416.1 kWh / yr
Annual Dollar Savings* $54.09 / yr
Commercial Facility Savings (25 Fixtures) $1352.25 / yr
50,000-Hr Commercial Life Savings $617.50

*Based on 12 hours/day usage at $0.13/kWh. System wattage includes ballast factor.

Recommended Replacements

Best options based on ROI and application needs for replacing a 150W HPS lamp.

Economy Choice
80–110W LED Corn Bulb Retrofit (E39 Mogul)

80–110W LED Corn Bulb Retrofit (E39 Mogul)

Direct screw-in retrofit. Bypasses the existing ballast to deliver full 14,400 lumens with lowest upfront equipment cost.

Power: 80–110W Efficiency: ~130–140 lm/W Base: E39 Mogul Wiring: Ballast Bypass (Type B)
Check Price on Amazon →
Best Value / ROI
80–110W UFO LED High Bay Fixture

80–110W UFO LED High Bay Fixture

Modern integrated fixture. Optimal thermal management, no legacy reflector losses, and fastest ROI with superior light distribution.

Power: 80–110W Lumens: 14,400 lm Mounting: Hook / Eye-bolt Warranty: 5 Years
Check Price on Amazon →
Premium / Pro
80–110W Commercial Grade Industrial LED Fixture

80–110W Commercial Grade Industrial LED Fixture

Heavy-duty industrial fixture with DLC certification for utility rebate eligibility. Engineered for continuous 24/7 commercial operation.

Rating: DLC Premium Listed Surge: 4–6kV Protection IP Rating: IP65 Wet Rated Warranty: 5–10 Years
Check Price on Amazon →

Engineering Analysis: 150W High-Pressure Sodium to LED Commercial Retrofit

Upgrading a commercial or industrial facility from 150-watt High-Pressure Sodium fixtures to solid-state LED systems delivers exceptional return on investment. With commercial utility rate structures, demand charges, and continuous 12-to-24 hour operational schedules, lighting retrofits frequently achieve full capital payback in under 12 to 18 months.

1. Initial vs. Mean Lumens: Why the Target Is 14,400 lm

A 150W High-Pressure Sodium lamp is rated at about 16,000 initial lumens, but averages roughly 14,400 mean lumens over its life, a 10% decline while still drawing full power. HPS holds its output better than most HID sources, so the gap is relatively small; its bigger weakness is color (CRI around 20–22). Quality LED products are rated by L70 (hours until output falls to 70% of initial), commonly 50,000 hours or more. That is why this page targets 14,400 mean lumens (real-world working light) rather than the initial rating.

2. Hidden Ballast Load

HID lamps cannot run directly on line voltage; they need a ballast (typically magnetic) to start and regulate the arc. For a 150W High-Pressure Sodium lamp, the ballast adds about 40W (27%), so the fixture draws roughly 190W at the meter. Converting to direct-wire Type B LED hardware removes the ballast completely, cutting demand from 190W to 80–110W.

3. Commercial Facility Savings & Demand Charge Reductions

Operating on an industrial duty cycle of 12 hours per day, 365 days per year:

4. Primary Applications for 150W High-Pressure Sodium Retrofits

In commercial and municipal applications, 150W High-Pressure Sodium fixtures are typically deployed in residential and collector streets (cobra-head fixtures), parking areas, building wall packs, and flood lights. The physical envelope corresponds to ED23½ (S55 lamps) or ED28 (S56 lamps) bulb, most often with an E39 mogul base.

System draw falls from about 190W to 80–110W, and the LED reaches full output instantly instead of warming up for several minutes.

HPS ignitors are a common failure point; a Type B conversion removes both the ignitor and the ballast.

Quick Reference: 150W HPS Lamp vs. LED Replacement

Spec150W HPS lampLED replacement
ANSI ballast codeS55 (55V) or S56 (100V)None (ballast removed)
Bulb & baseED23½ (S55 lamps) or ED28 (S56 lamps) bulb, most often with an E39 mogul baseCorn bulb on the same base, or an integrated fixture
Light output16,000 initial / 14,400 mean lm14,400 lm target
Power at the meter~190W including ballast80–110W
Color~2,000–2,100K, CRI ~20–222700K–5000K, CRI 70–80+
Rated life24,000+ hours50,000+ hours (L70), typical
Warm-up / restrikeSeveral minutes / about 1 minuteInstant

What's Specific to the 150W HPS Retrofit

Two incompatible 150W lamps

150W HPS is sold in two electrically different versions: ANSI S55 (55-volt arc) and ANSI S56 (100-volt arc). They look alike but are not interchangeable on a ballast. If you need a stopgap HPS lamp, match the code on the fixture label. With a Type B LED conversion the distinction disappears, because the ballast is removed.

Cobra heads waste corn-bulb light

In a cobra-head street fixture the lamp lies sideways inside a reflector. Corn bulbs emit light from all sides, so a large share hits the housing instead of the road. In these fixtures, replacing the whole head with an integrated LED roadway or area light usually puts more light on the ground per watt than a screw-in retrofit.

Color temperature for streets

For residential and collector streets, follow the AMA's 2016 recommendation of 3000K or lower. Reserve 4000K for commercial lots where camera clarity matters more than nighttime glare.

Sizing From Delivered Light (Worked Example)

The 14,400 lm target above is a lamp-for-lamp match, which is the safe choice for a screw-in corn bulb. If you are replacing the whole fixture, you can often target fewer lumens. HID lamp ratings describe the bare lamp, and part of that light is lost inside the housing and reflector, while LED fixture ratings are measured for the complete fixture (IES LM-79 absolute photometry).

Example: if your existing fixture is 70% efficient, it delivers about 10,100 lm. An LED fixture producing 10,100 lm at 130 lm/W draws about 80W, versus ~190W today. Treat this as an estimate; the fixture maker's photometric report or a lighting layout is the authoritative answer.

5. Commercial Installation: Type B Ballast-Bypass Protocol

For maximum electrical efficiency and long-term reliability, a Type B (ballast-bypass) conversion is standard engineering practice:

  1. Disconnect Power: Lock out and tag out the circuit breaker supplying the lighting circuit.
  2. Bypass the Ballast: Disconnect the incoming line voltage (120–277V) and neutral wires from the legacy magnetic or electronic ballast. Cut or remove the ballast entirely, along with the ignitor and capacitor if the fixture has them (an ignitor left in the circuit sends high-voltage pulses that can destroy an LED driver).
  3. Wire Directly to Sockets: Connect line voltage directly to the socket leads according to the manufacturer's installation diagram.
  4. Label the Fixture: Affix the provided warning label inside the fixture housing indicating that the fixture has been modified to run line voltage and will no longer accept legacy High-Pressure Sodium lamps.
⚠️ CRITICAL SAFETY WARNING: High-output commercial LED retrofits require proper ballast disconnection. Powering a Type B direct-wire LED lamp through an active ballast will damage the internal driver and can create an electrical hazard. Always verify circuit voltage and wiring before restoring power. Installation by a licensed commercial electrician is strongly advised.